To access all features and enjoy the full functionality of this site, please ensure your browser is up-to-date. For IE8 users, the most recent version is IE11.

SENSARTM Monofocal 1-Piece IOL

SENSARTM Monofocal 1-Piece IOL

To order this product, please contact your sales rep.

Reliable, High-Quality Monofocal Vision

Designed to reduce chromatic aberration and produce long-term performance, the SENSARTM IOL can help you give your patients the reliable, quality vision associated with our monofocal IOLs.1  

The SENSARTM IOL offers the high-quality lens design, materials and optics that can be expected from Johnson & Johnson Vision intraocular lenses.

  • Hydrophobic material is not associated with glistenings2
  • ProTEC 360° edge design helps limit LEC migration3
  • Higher Abbe number compared to competing acrylic IOLs4
  • Reduces the transmission of UV light while still allowing blue light, which has proven to be essential for maintaining optimal scotopic vision5

Model:

AAB00

OPTIC CHARACTERISTICS1

Powers:

+6.0 D to 30.0 D in 0.5 diopter increments

Diameter:

6.0 mm

Material:

UV-absorbing hydrophobic acrylic

Refractive Index:

1.47 at 35˚ C

Edge Design:

ProTEC frosted, continuous 360˚ posterior square edge

ULTRASOUND BIOMETRY*

A-Constant:

118.4

Theoretical AC Depth:

5.2 mm

Surgeon Factor:6

1.45 mm

HAPTIC CHARACTERISTICS1

Overall Diameter:

13.0 mm

Style:

C

Material:

UV-absorbing hydrophobic acrylic

Design:

Haptics offset from optic

IOL INSERTION

Recommended insertion instruments:

UNFOLDERTM Platinum 1 Series Delivery System: Intuitive push-and-twist, screw-style insertion designed to simplify lens implantation.

FOOTNOTES

*Value theoretically derived for a typical 20.0 D lens. Johnson & Johnson Vision recommends that surgeons personalize their A-constant based on their surgical techniques and equipment, experience with the lens model, and postoperative results.

 

REFERENCES

1. SENSARTM 1-Piece IOL - DfU INT - Z311129, Rev. C, 09/2019. REF2021OTH4865. 
2. 150 – Data on File – Sensar not associated with glistening – Literature analysis. May 2013. REF2014OTH0002.
3. Nixon DR, Woodcock MG. Pattern of posterior capsule opacification models 2 years postoperatively with 2 single-piece acrylic intraocular lenses. J Cataract Refract Surg 2010;36(6):929-934. REF20140020.
4. Zhao H, Mainster MA. The effect of chromatic dispersion on pseudophakic optical performance. Br J Ophthalmol. 2007;91(9):1225-1229. REF20140029.
5. Mainster MA. Violet and blue-light blocking intraocular lenses: Photoprotection versus photoreception. Br J Ophthalmol. 2006;90:784-792. REF2014MLT0013.
6. Holladay JT. International Intraocular Lens & Implant Registry 2003. J Cataract Refract Surg. 2003; 29:176-197. REF2016CT0151.

 

© Johnson & Johnson Surgical Vision, Inc. 2022.

For healthcare professionals only. Please reference the Instructions for Use for a complete list of Indications and Important Safety Information and contact our specialists in case of any question

PP2022MLT4205