To access all features and enjoy the full functionality of this site, please ensure your browser is up-to-date. For IE8 users, the most recent version is IE11.

SENSARTM Monofocal 3-Piece IOL

Reliable, High-Quality Monofocal Vision

Designed to produce long-term performance, the SENSAR™ IOL can help you give your patients the reliable, quality vision associated with our monofocal IOLs.1,2  

The SENSAR™ IOL offers the high-quality lens design, materials and optics that can be expected from Johnson & Johnson Vision intraocular lenses.

  • Hydrophobic material is not associated with glistenings3
  • Higher Abbe number compared to competing acrylic IOLs4
  • Reduces the transmission of UV light while still allowing blue light, which has proven to be essential for maintaining optimal scotopic vision5
Model:  AR40M AR40E AR40e
OPTIC CHARACTERISTICS1,2
Powers: -10.0 D to + 1.5 D in 0.5 diopter increments +2.0 to +5.5 D in 0.5 diopter increments

+6.0 D to +12.0 D and +26.0 to +30.0 D in 1.0 diopter increments

+12.0 D to in 0.+25.5 D in 0.5 diopter increments
Diameter: 6.0 mm 6.0 mm 6.0 mm
Shape: Meniscus Biconvex Biconvex
Material: UV-absorbing hydrophobic acrylic UV-absorbing hydrophobic acrylic UV-absorbing hydrophobic acrylic
Refractive Index: 1.47 at 35° C 1.47 at 35° C 1.47 at 35° C
Edge Design: OptiEdge with 360° square posterior edge and round anterior edge
OPTICAL BIOMETRY6
A-constant (SRK/T): 118.7 118.7 118.7
AC depth (HofferQ): 5.41 mm 5.41 mm 5.39 mm
Surgeon Factor (Holl1): 1.63 mm 1.63 mm 1.62 mm
APPLANATION ULTRASOUND BIOMETRY
A-constant: 118.4
AC depth: 5.2 mm
Surgeon Factor:7 1.45 mm
HAPTIC CHARACTERISTICS1,2
Overall Length: 13.5 mm 13.5 mm 13.0 mm
Style: Modified C Modified C Modified C
Material: Blue core polymethylmethacrylate (PMMA) monofilament

 

IOL INSERTION

Recommended insertion instruments:

UNFOLDERTM EMERALD T Series Delivery System: Intuitive push-and-twist, screw-style insertion designed to simplify lens implantation.

FOOTNOTES

† A-Constant theoretically derived for ultrasound biometry.

 

REFERENCES

1. SENSAR™ 3-p AR40e - 10.0 -  +30.0 D - DfU OUS - Z311122P, Rev. C, 09/2019. REF2020CT4139.
2. SENSAR™ 3-p AR40E-AR40M - 10.0 - +5.5D - DfU OUS - Z311124P, Rev. C, 09/2019. REF2020CT4138.

3. 150 – Data on File – SENSAR™ not associated with glistening – Literature analysis. May 2013. REF2014OTH0002.
4. Zhao H, Mainster MA. The effect of chromatic dispersion on pseudophakic optical performance. Br J Ophthalmol. 2007;91(9):1225-1229. REF20140029.
5. Mainster MA. Violet and blue-light blocking intraocular lenses: Photoprotection versus photoreception. Br J Ophthalmol. 2006;90:784-792. REF2014MLT0013.
6. IOLCon website https://iolcon.org. Status 6 March 2019. REF2021MLT4006.
7. Holladay JT. International Intraocular Lens & Implant Registry 2003. J Cataract Refract Surg. 2003; 29:176-197. REF2016CT0151.

 

For healthcare professionals only. Please reference the Instructions for Use for a complete list of Indications and Important Safety Information and contact our specialists in case of any question

© Johnson & Johnson Surgical Vision, Inc. 2022.

PP2022CT5545