To access all features and enjoy the full functionality of this site, please ensure your browser is up-to-date. For IE8 users, the most recent version is IE11.

TECNISTM Multifocal IOL +4.0 D

TECNISTM Multifocal IOL +4.0 D

To order this product, please contact your sales rep.

Outstanding, Full-Range Vision Tailored for Near Distances

Engineered to help you meet unique visual demands, TECNISTM Multifocal IOLs allow you to deliver tailored clarity that suits your patients’ daily needs. The TECNISTM Multifocal IOL +4.0 D delivers a full range of sharp vision tailored for near distances.1  

 

The TECNISTM Multifocal IOL +4.0 D is designed with your patients in mind. Optimized for those favoring near-vision activities like reading and knitting, it delivers tailored clarity at a theoretical reading distance of 33 cm.

Binocular Defocus Curve at 6 Months2,3

 

Distances (cm) in the graph are approximate. +4.0D data are historical from a separate clinical study using the same test methodology.

The TECNISTM Multifocal Family of 1-Piece IOLs features the only multifocal lenses capable of providing a full range of high-quality vision (20/25 or better),1-3 tailored for each patient’s lifestyle.

  • Sharp vision across near, intermediate and distance vision1
  • Optimized for a theoretical reading distance of 33.0 cm with the +4.0 D lens4

Give your patients a lens designed for real-world performance.

How Often Do You Wear Glasses?*3-4

 

+4.0 D (purple) data are historical from a separate clinical study using the same test methodology.

 

Degree of Difficulty** With Night Vision*3,4

+4.0 D (purple) data are historical from a separate clinical study using the same test methodology.

Unlike another leading IOL, TECNISTM IOL material is not associated with
glistenings,6-10 which can inhibit your patients’ vision. Glistenings cause light
scatter, which can result in a reduction in image contrast.7-11

 

Model

ZMB00

OPTIC CHARACTERISTICS1

Powers:

+5.0 D to 34.0 D in 0.5 diopter increments

Diameter:

6.0 mm

Shape:

Biconvex, anterior aspheric surface, posterior diffractive surface

Add Power (IOL Plane):

+4.0 D

Add Power (Spec Plane):

+3.0 D

Material:

UV-absorbing hydrophobic acrylic

Refractive Index:

1.47 at 35° C

Chromatic Aberration (Abbe Number):

55

Edge Design:

ProTEC frosted, continuous 360° posterior square edge

BIOMETRY

CONTACT ULTRASOUND

OPTICAL

A-Constant:

118.8

119.3

Theoretical AC Depth:

5.40 mm

5.72 mm

Surgeon Factor:12

1.68 mm

1.96 mm

HAPTIC CHARACTERISTICS1

Overall Diameter:

13.0 mm

Style:

C

Material:

UV-absorbing hydrophobic acrylic

Design:

Haptics offset from optic

IOL INSERTION

Recommended insertion instruments:

FOOTNOTES

*The questionnaire was not determined to be a psychometrically valid assessment of the concept of spectacle independence.

**On a scale of 1-7, with glasses as needed

†Value theoretically derived for a typical 20.00 D lens. Johnson & Johnson Vision recommends that surgeons personalize their A-constant based on their surgical techniques and equipment, experience with the lens model and postoperative results.

‡Derived from clinical evaluation results of the TECNISTM 1-Piece IOL Platform.

 

REFERENCES

1. TECNISTM MF 1-Piece IOL, Model ZMB00 - DfU INT - Z311335, Rev. 02, June 2019. REF2020CT4082.
2. SSED TECNISTM MF ZM900-ZMA00, P0800010, Jan 16,2009. REF2015OTH0648.
3. Data on File - Terwee T. Optical Performance of the TECNISTM Multifocal IOLs ZMA00 and ZMB00 measured in-vitro in an eye model in green and white light, in comparison with the competitor MF IOLs AcrySOF ReSTOR SN5AD1 (Alcon), Acri.Lisa 356D (Zeiss) and CrystaLens HD500 (Bausch & Lomb). Sep. 8, 2009. REF2014CT0046.
4. FDA - The TECNISTM Multifocal 1-Piece IOLs, Models ZKB00, ZLB00 and ZMB00,  Patient Information Brochure. REF2015CT0285.
5. SSED TECNISTM MF ZKB00 - ZLB00, P980040/S049. Dec. 17, 2014. REF2015OTH0646.
6. 150 - Data on File – Sensar not associated with glistenings – Literature analysis. 2013. REF2014OTH0002. 
7. Nagata M, et al. Clinical evaluation of the transparency of hydrophobic acrylic intraocular lens optics. J Cataract Refract Surg. 2010;36(12):2056-2060. REF2015CT0080.
8. Christiansen G, et al. Glistenings in the AcrySof® intraocular lens: Pilot study. J Cataract Refract Surg. 2001;27(5):728-733. REF2014MLT0005.
9. Colin J, et al. Incidence of glistenings with the latest generation of yellow- tinted hydrophobic acrylic intraocular lenses. J Cataract Refract Surg. 2012;38(7):1140-1146. REF2014MLT0006.
10. Gunenc U, et al. Effects on visual function of glistenings and folding marks in AcrySof® intraocular lenses. J Cataract Refract Surg. 2001;27(10):1611-1614. REF2014MLT0011.
11. Van der Mooren M, Franssen L, Piers P. Effects of glistenings in intraocular lenses. Biomed Opt Express. 2013;4(8):1294-1304. REF2014OTH0139. 
12. Calculated based on Holladay I formula: Holladay JT, Prager TC, Chandler TY, Musgrove KH, Lewis JW, Ruis RS. A three-part system for refining intraocular lens power calculations. J Cataract Refract Surg. 1988;14(1):17-24. REF2014CT0092.
 

 

© Johnson & Johnson Surgical Vision, Inc. 2022.

For healthcare professionals only. Please reference the Instructions for Use for a complete list of Indications and Important Safety Information and contact our specialists in case of any question

 
PP2022MLT4205