To access all features and enjoy the full functionality of this site, please ensure your browser is up-to-date. For IE8 users, the most recent version is IE11.

TECNISTM Toric II 1-Piece IOL

TECNISTM Toric II 1-Piece IOL

To order this product, please contact your sales rep. 
May not be available for all countries.

 

 

Get a Grip on Visual Performance

With its squared and frosted haptic design the TECNIS™ Toric II platform delivers exceptional rotational stability.1

TECNIS™ Toric 1-Piece IOL (non-frosted)                TECNIS™ Toric II 1-Piece IOL (frosted)

  • 100% of surgeries had less than 5° rotation at 3-months1
  • Mean rotation of TECNIS™ Toric II IOL was 0.94° at 3-months postoperatively1
  • As much as 31% improved image contrast over AcrySof® IQ IOLs2
  • Proven low-light performance2
  • High-quality distance vision1

Optimize your outcomes with the TECNIS Toric Calculator.

Leverage toric IOLs to reduce residual refractive cylinder and increase spectacle independence for distance.3,4

  • 94% of eyes achieve ≤ 0.50 diopters of residual refractive cylinder3
  • 94.7% of patients achieved binocular uncorrected distance visual acuity of 20/20 or better4

Unlike another leading IOL, TECNIS™ IOL material is not associated with glistenings,5-9 which can inhibit your patients’ vision. Glistenings cause light scatter, which can result in a reduction in image contrast.6-10

Unlike another leading IOL, TECNIS™ IOL material is not associated with
glistenings,5-9 which can inhibit your patients’ vision. Glistenings cause light scatter, which can result in a reduction in image contrast.6-10

97% of patients would elect to have the TECNIS™ Toric IOL again.3

OPTIC CHARACTERISTICS11

Powers:

+5.0 D to +34.0 D in 0.5 diopter increments.                                                                 

Model Numbers:
ZCU100
ZCU150 ZCU225 ZCU300 ZCU375 ZCU450 ZCU525 ZCU600 ZCU700 ZCU800
Cylinder Powers – IOL Plane: 1.00 D 1.50 D 2.25 D 3.00 D 3.75 D 4.50 D 5.25 D 6.00 D 7.00 D 8.00 D
Cylinder Powers – Corneal Plane: 0.69 D 1.03 D 1.54 D 2.06 D 2.57 D 3.08 D 3.60 D 4.11 D 4.80 D 5.48 D

Diameter:

6.0 mm

Shape:

Biconvex, anterior toric aspheric surface, square optic edge

Material:

UV-absorbing hydrophobic acrylic

Refractive Index:

1.47 at 35° C

Edge Design:

ProTEC frosted, continuous 360° posterior square edge

BIOMETRY

CONTACT ULTRASOUND§

OPTICAL*,‡

A-Constant:

118.8

119.3

Theoretical AC Depth:

5.4 mm

5.7 mm

Surgeon Factor:12

1.68 mm

1.96 mm

HAPTIC CHARACTERISTICS11

Overall Length:

13.0 mm

Configuration:

Tri-Fix design, modified C, integral with optic

Material:

UV-absorbing hydrophobic acrylic

Design:

Haptics offset from optic, haptics have a squared and frosted design

IOL INSERTION

Recommended insertion instruments:

FOOTNOTES

* Based on average pseudophakic human eye and ‘Holladay et al. A three-part system for refining intraocular lens power calculations. J Cataract Refract Surg. 1988;14(1):17-24. REF2014CT0092.

Derived from clinical evaluation results of the TECNIS™ 1-Piece IOL Platform for optical biometry.

§ A-Constant theoretically derived for ultrasound biometry.

 

REFERENCES

1. DOF2021CT4019 – Clinical Investigation of Rotational Stability of the TECNIS™ Toric II IOL – From Study NXGT-202-QROS. 20 Aug. 2021.
2. DOF2015OTH0006 – TECNIS™ and competitor toric IOL MTF data. 4 May 2015.
3. Black D. Efficacy of hydrophobic acrylic toric IOL to correct astigmatism in cataract patients. Presented at ASCRS 2015. REF2015CT0193.
4. Post-Approval Study of the TECNIS™ Toric IOL Extended Cylinder Range (ECR), Models ZCT450, ZCT525 and ZCT600. 30 August 2017. REF2018CT4111.
5. 150 – Data on File – SENSAR™ not associated with glistening – Literature analysis. May 2013. REF2014OTH0002.
6. Nagata M, et al. Clinical evaluation of the transparency of hydrophobic acrylic intraocular lens optics. J Cataract Refract Surg. 2010;36(12):2056-2060. REF2015CT0080.
7. Christiansen G, et al. Glistenings in the AcrySof® intraocular lens: Pilot study. J Cataract Refract Surg. 2001;27(5):728-733. REF2014MLT0005.
8. Colin J, et al. Incidence of glistenings with the latest generation of yellow-tinted hydrophobic acrylic intraocular lenses. J Cataract Refract Surg. 2012;38(7):1140-1146. REF2014MLT0006.
9. Gunenc U, et al. Effects on visual function of glistenings and folding marks in AcrySof® intraocular lenses. J Cataract Refract Surg. 2001;27(10):1611-1614. REF2014MLT0011.
10. Van der Mooren M, Franssen L, Piers P. Effects of glistenings in intraocular lenses. Biomed Opt Express. 2013;4(8):1294-1304. REF2014OTH0139.
11. TECNIS™ Toric II IOL, Model ZCU100-ZCU800 – DfU OUS – Z311613, current revision.
12. Holladay JT. International Intraocular Lens & Implants registry 2003. J Cataract Refract Surg. 2003;29:176-197. REF2016CT0151.

 
© Johnson & Johnson and its affiliates 2024
 
For healthcare professionals only. Please reference the Instructions for Use for a complete list of Indications and Important Safety Information and contact our specialists in case of any question.

2024PP15294